Cubigo VMS - Hardware installation
Uniview - Settings reset quick guide
A thermal scanner settings reset might be necessary when the Visit app was able to connect to the scanner but wasn’t able to receive scan results.
In that case, you don’t see the page with “Connecting to hardware” but you directly see this page and the error page on the right after 2 minutes.
Uniview Thermal Scanner - OET-213H-BTS1-BD
STEP 1 - Perform a settings reset in the Uniview web interface
- Open a web browser and enter the scanner’s IP address in the address bar
- Log in with the admin user and password
- Click on Setup - System - Maintenance
- Click on the “Default” button in the “Config management” section.
The user and internet settings stay unchanged, so you should be able to go back to the web interface after the settings are reverted.
STEP 2 - Reconfigure the interface and branding settings (if necessary)
- Log in again in the web interface
- Go to setup - Common - Personalization
- Check title and/or logo in “Custom logo and Prompt” tab - click Save
- Hide all buttons in the “Custom button” tab - click save
STEP 3 - Configure the volume and authentication settings using the scanner’s display
We updated these steps because they are easier to configure on the scanner’s display.
- Go to the thermal scanner and tick 5 seconds on the screen
- Enter the admin password and click “Enter”
- Tick on the “Volume” cube
- Adjust the volume to 0
- Tick save and wait for the confirmation popup
- Tick the left arrow to go back to the screen with the cubes
- Open the “Authentication scene” cube
- Choose authentication scene “Temperature measurement Only”
- Choose the desired unit (Celsius or Fahrenheit)
- Check (or adjust) the alarm threshold.
- Tick save and wait for the confirmation popup
- Go back and exit the settings menu.